Manufactured from certified plate (e.g., S235–S355) via laser/plasma cutting, CNC drilling/milling, and qualified welding (WPS/PQR). Stud welding (EN ISO 14555) and rebar anchoring assemblies available. Dimensional checks per drawings; marking and packing by set.
Materials and processes adhere to recognized standards for structural fabrication and coating.
Used in steel-to-concrete or steel-to-steel connections: base plates for columns, beam seat plates, façade brackets, machine anchor plates, and precast embeds requiring accurate hole layouts and high load transfer.
Plate Size (mm) | Thickness (mm) | Bolt Pattern | Anchor Type | Finish |
---|---|---|---|---|
200×200 | 12 | 4× M16 @ 140 PCD | Through-bolts | Shop-primed |
300×300 | 20 | 4× M20 @ 220 PCD | Headed studs M16×120 | HDG (EN ISO 1461) |
400×300 | 25 | 6× M24 grid 3×2 @ 100 | Headed studs M20×150 | Shot-blasted SA 2½ + primer |
500×500 | 30 | 8× M24 @ 350 PCD + slot 18×30 | Rebar anchors Ø16 L=600 | HDG |
600×400 | 40 | 8× M30 grid 4×2 @ 150 | Headed studs M24×180 | Shop-primed (C3 system) |